RIFF JTAG Box setup: How to set up RIFF Box Answer: System Requirements:
Windows XP, Windows Vista or Windows 7 based PC (Windows 8/10 is also tested)
Display resolution 1280x1024 or more
At least 4GB free space for RIFF ...
Useful Plugins: How to use RIFF Box eMMC EFI/PIT/MBR/EBR Partitioning plugin Answer: This plugin works with eMMC image files and phones which have following formatting:1. Image Files or Phones with Standard Master Boot Record (MBR) and Extended ...
RIFF JTAG Error codes and troubleshooting: Error code 0x43 Answer: 1.8. Error code 0x43
Returned by the box’s firmware when target HALT operation was performed on already halted target.
Solution:
Don't halt already halted target ! ...
RIFF JTAG Error codes and troubleshooting: ERROR: Wrong response code from the RIFF Box: 0x44 Answer: 1.9. Error code 0x44
Returned by the box’s firmware if attempted target HALT operation failed.
Solution:
Check target device connection. In case You're trying to access device based ...
RIFF JTAG Error codes and troubleshooting: ERROR: Read/Write memory failed during H/W Init Answer: ERROR: Read/Write memory failed during H/W Init
This error can happen due to few reasons:
NRST or GND pins not connected properly
Wrong model selected
Hardware failure
Solution:
Connect NRST and ...
RIFF JTAG Error codes and troubleshooting: ERROR: Set I/O Voltage failed. Real reading is "value" Answer: ERROR: Set I/O Voltage to"value" failed. Real reading is "value".
Can happen due to following reasons:
Connection with device is wrong
Target device has developed hardware malfunction
RIFF Box ...
RIFF JTAG Error codes and troubleshooting: ERROR: No response from the RIFF Box. Answer: ERROR: No response from the RIFF Box.
Can happen due to numerous of reasons. Mostly it's caused by wrongly configured RTCK/TCK sampling value, or badly connected ...
RIFF JTAG Error codes and troubleshooting: ERROR: The RTCK Signal does not respond. Answer: ERROR: The RTCK Signal does not respond.
Can happen due to numerous of reasons:
RTCK not connected
RTCK signal doesn't exist for current target device
Target device is wrongly ...
RIFF JTAG Error codes and troubleshooting: Failed to receive answer to READ command. Answer: Failed to receive answer to READ command.
This error happens mostly due to high RTCK/TCK sampling rate. If You're using "Sample at Max" RTCK settings, set ...
RIFF JTAG Error codes and troubleshooting: ERROR: RAM memory selftest failed. Answer: ERROR: RAM memory selftest failed.
This error can be caused by numerous reasons. In most cases, it's due to bad connection (unstable NRST signal line), or ...