  • RIFF JTAG Box setup: How to set up RIFF Box
    Answer: System Requirements: Windows XP, Windows Vista or Windows 7 based PC (Windows 8/10 is also tested) Display resolution 1280x1024 or more At least 4GB free space for RIFF ...
  • Useful Plugins: How to use RIFF Box eMMC EFI/PIT/MBR/EBR Partitioning plugin
    Answer: This plugin works with eMMC image files and phones which have following formatting:1.    Image Files or Phones with Standard Master Boot Record (MBR) and Extended ...
  • RIFF JTAG Error codes and troubleshooting: Error code 0x43
    Answer: 1.8. Error code 0x43 Returned by the box’s firmware when target HALT operation was performed on already halted target.   Solution: Don't halt already halted target !  ...
  • RIFF JTAG Error codes and troubleshooting: ERROR: Wrong response code from the RIFF Box: 0x44
    Answer: 1.9. Error code 0x44 Returned by the box’s firmware if attempted target HALT operation failed.   Solution: Check target device connection. In case You're trying to access device based ...
  • RIFF JTAG Error codes and troubleshooting: ERROR: Read/Write memory failed during H/W Init
    Answer: ERROR: Read/Write memory failed during H/W Init This error can happen due to few reasons: NRST or GND pins not connected properly Wrong model selected Hardware failure Solution: Connect NRST and ...
  • RIFF JTAG Error codes and troubleshooting: ERROR: Set I/O Voltage failed. Real reading is "value"
    Answer: ERROR: Set I/O Voltage to"value" failed. Real reading is "value".   Can happen due to following reasons: Connection with device is wrong Target device has developed hardware  malfunction RIFF Box ...
  • RIFF JTAG Error codes and troubleshooting: ERROR: No response from the RIFF Box.
    Answer: ERROR: No response from the RIFF Box.   Can happen due to numerous of reasons. Mostly it's caused by wrongly configured RTCK/TCK sampling value, or badly connected ...
  • RIFF JTAG Error codes and troubleshooting: ERROR: The RTCK Signal does not respond.
    Answer: ERROR: The RTCK Signal does not respond.   Can happen due to numerous of reasons: RTCK  not connected RTCK signal doesn't exist for current target device Target device is wrongly ...
  • RIFF JTAG Error codes and troubleshooting: Failed to receive answer to READ command.
    Answer: Failed to receive answer to READ command.   This error happens mostly due to high RTCK/TCK sampling rate. If You're using "Sample at Max" RTCK settings, set ...
  • RIFF JTAG Error codes and troubleshooting: ERROR: RAM memory selftest failed.
    Answer: ERROR: RAM memory selftest failed.   This error can be caused by numerous reasons. In most cases, it's due to bad connection (unstable NRST signal line), or ...